Model PRO901W (S/L/SI/LI) PRO902 (S/L/SI/LI) PRO903 (S/L/SI/LI) PRO906 (S/L/SI/LI)
Capacity Volt-Amp
  • 1000 VA
  • 2000 VA
  • 3000 VA
  • 6000 VA
Watt
  • 800 W
  • 1600 W
  • 2400 W
  • 4800 W
Phase
  • Single Phase In / Single Phase Out
Isolation Transformer
  • Optional
Input
Input AC Voltage
  • 208/220/230/240VAC or 110/115/120/127VAC
  • 208/220/230/240VAC
Voltage Range Low Line Transfer
  • 160/140/120/110VAC ±5% or 80/70/60/50VAC ±5% #1
  • 175/150/130/110VAC ±5% #1
Low Line Comeback
  • 168/148/128/118VAC ±5% or 84/74/64/54VAC ±5% #1
  • 183/158/138/118VAC ±5% #1
Low Line Comeback
(Auto Restart)
  • 168VAC ±5% or 84VAC ±5% (80%~ 100% Load)
    148VAC ±5% or 74VAC ±5% (0%~ 80% Load)
  • 180VAC ±5% (80%~ 100% Load)
    155VAC ±5% (0%~ 80% Load)
High Line Transfer
  • 300VAC ±5% or 150VAC ±5%
  • 280VAC ±5%
High Line Comeback
  • 290VAC ±5% or 145VAC ±5%
  • 270VAC ±5%
Frequency Range
  • 40~70Hz (Auto Sensing)
Power Factor
  • ≥ 0.98 @Nominal Voltage (100% load)
Output
Output AC Voltage
  • 208/220/230/240VAC or 110/115/120/127VAC
AC Voltage Regulation (Battery Mde)
  • ±1%
  • ±3%
Frequency Range Synchronized Range
  • 47~53Hz or 57~63Hz
Battery Mode
  • 50Hz ±0.25Hz or 60Hz ±0.3Hz
Current Crest Ratio
  • 3:1
Harmonic Distortion Linear Load
  • ≤3% THD
  • ≤4% THD
  • ≤3% THD
Non-Linear Load
  • ≤6% THD
  • ≤7% THD
  • ≤6% THD
Transfer Time AC Mode to Battery Mode
  • Zero
Inverter to Bypass
  • 4ms (Typical)
Waveform (Battery Mode)
  • Pure Sinewave
Effciency
AC Mode
  • 88.5%
  • >89.3%
  • 87%
  • 90%
Battery Mode
  • 83.7%
  • 88.2%
  • 85%
  • 85%
Battery
Standard Model Battery Type
  • 12V9AH
  • 12V10AH
Numbers
  • 2
  • 4
  • 6
  • 8
Typical Recharge Time
  • 9 hours recover to 90% capacity
Charging Current (max.)
  • 1A
Charging Voltage
  • 27.4VDC ±1%
  • 54.7VDC ±1%
  • 82.1VDC ±1%
  • 109.4VDC ±1%
Long-Run Model Battery Type
  • Depending on applications
Numbers
  • 2
  • 4
  • 6
  • 8
Charging Current (max.)
  • 1A/5A
  • 1A/2A/4A/8A
  • 4A/8A
  • 4A/8A, 10A (Optional)
Charging Voltage
  • 27.4VDC ±1%
  • 54.7VDC ±1%
  • 82.1VDC ±1%
  • 109.4VDC±1%
Indicators
LCD Panel
  • UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
Alarm
Battery Model
  • Sounding every 4 seconds
Low Battery
  • Sounding every seconds
Overload
  • Sounding twice every seconds
Fault
  • Continuously sounding
Physical
Standard Model Dimension (mm) D×W×H
  • 397×145×220
  • 421×190×318
  • 426×190×318
Net Weight (kgs)
  • 10.8
  • 17.2
  • 28.7
  • 36.2
Long-Run Model Dimension (mm) D×W×H
  • 397×145×220
  • 421×190×318
  • 426×190×318
Net Weight (kgs)
  • 5.7
  • 8.9
  • 13.1
  • 15.2
Environment
Humidity
  • 20-90% Relative Humidity @ 0~40°C (Non-Condensing)
Noise Level
  • Less than 45dB @ 1 Meter
  • Less than 55dB @ 1 Meter
Regulations
  • EN 62040-2:2006, EN 61000-3-2:2006+A1:2009+A2:2009, EN 61000-3-3:2008
Management
Smart RS232
  • Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
Package Content

Included

  • Please contact regional sales staff for details.