• Prolink Sl 1
  • Prolink Sl 2
  • Prolink Sl 3
  • Prolink Sl 4
  • Prolink Sl 5

Prolink 1KVA online Pro801ERS Rack/Tower (Mã: )

0 đ
Thương hiệu: prolink
Số lượng:
Model PRO801 (RS/RL) PRO8015(RS/RL) PRO802 (RS/RL) PRO803 (RS/RL) PRO806 (RS/RL) PRO810 (RS/RL)
Capacity Volt-Amp
  • 1000 VA
  • 1500 VA
  • 2000 VA
  • 3000 VA
  • 6000 VA
  • 10000 VA
Watt Standard Model
  • 900 W
  • 1350 W
  • 1800 W
  • 2700 W
  • 5400 W
  • 9000 W
Long-Run Model
  • 800 W
  • 1200 W
  • 1500 W
  • 2400 W
  • 5400 W
  • 9000 W
Phase
  • Single Phase In / Single Phase Out
Input
Voltage Range Low Line Transfer
  • 80/70/60/55VAC ±5% or 160/140/120/110VAC ±5% #1
  • 176 VAC ±3% @ 100% Load or 110 VAC ±3% @ 50% Load
Low Line Comeback
  • 85/75/65/60VAC ±5% or 170/150/130/120VAC ±5%
  • 186 VAC ±3% @ 100% Load or 120 VAC ±3% @ 50% Load
High Line Transfer
  • 150VAC ±5% or 300VAC ±5%
  • 300VAC ±3%
High Line Comeback
  • 140VAC ±5% or 290VAC ±5%
  • 290VAC ±3%
Frequency Range
  • 40~70Hz
  • 46~54Hz or 56Hz~64Hz
Power Factor Correction
  • ≥ 0.99 @ nominal voltage (100%load)
  • ≥ 0.99 @ 100% Load
Output
Output Voltage
  • 110/115/120/127VAC or 208/220/230/240VAC
  • 208/220/230/240VAC
AC Voltage Regulation (Battery Mode)
  • ±1%
  • ±1%
Frequency Range Synchronized Range
  • 47~53Hz or 57~63Hz
  • 46~54Hz or 56~64Hz
Battery Mode
  • 50Hz ±0.2Hz or 60Hz ±0.2Hz
  • 50Hz ±0.1Hz or 60Hz ±0.1Hz
Current Crest Ratio
  • 5:1 (max.)
  • 3:1
Harmonic Distortion Linear Load
  • ≤ 2% THD
  • ≤ 2% THD
Non-Linear Load
  • ≤ 8% THD
  • ≤ 6% THD
Transfer Time AC Mode to Battery Mode
  • Zero
Inverter to Bypass
  • Zero
Waveform (Battery Mode)
  • Pure Sinewave
Efficiency
AC Mode
  • 86%
  • 88%
  • 90%
Battery Mode
  • 83%
  • 85%
  • 88%
Battery
Standard Model Battery Type
  • 12V9AH
  • 12V7AH
  • 12V9AH
Numbers
  • 2
  • 3
  • 4
  • 6
  • 20
  • 20
Typical Recharge Time
  • 4 hours recover to 90% capacity
  • 9 hours recover to 90% capacity
Charging Current (max.)
  • 1A
Charging Voltage
  • 27.4VDC ±1%
  • 41.1VDC ±1%
  • 54.7VDC ±1%
  • 82.1VDC ±1%
  • 273VDC ±1%
Long-Run Model Battery Type Depending on applications
Numbers
  • 2
  • 3
  • 4
  • 6
  • 20
Charging Current (max.)
  • 4A/8A
  • 4A
Charging Voltage
  • 27.4VDC ±1%
  • 41.1VDC ±1%
  • 54.7VDC ±1%
  • 82.1VDC ±1%
  • 273VDC ±1%
Indicators
LCD Panel
  • UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
Alarm
Battery Model
  • Sounding every 4 seconds
Low Battery
  • Sounding every seconds
Overload
  • Sounding twice every seconds
Fault
  • Continuously sounding
Physical
Standard Model Dimension (mm) D×W×H
  • 380×438×88 [2U]
  • 480×438×88 [2U]
  • 480×438×88 [2U]
  • 600×438×88 [2U]
  • UPS Unit : 580×438×133 [3U]
    Battery Pack : 580×438×133 [3U]
  • UPS Unit : 668×438×133 [3U]
    Battery Pack : 580×438×133
Net Weight (kgs)
  • 12.9
  • 17.6
  • 20.6
  • 28
  • UPS Unit : 17
    Battery Pack : 57
  • UPS Unit : 20
    Battery Pack
Long-Run Model Dimension (mm) D×W×H
  • 380×438×88 [2U]
  • 480×438×88 [2U]
  • 480×438×88 [2U]
  • 600×438×88 [2U]
  • 580×438×133 [3U]
  • 668×438×13
Net Weight (kgs)
  • 8.6
  • 10.7
  • 11.3
  • 13.8
  • 17
  • 20
Environment
Humidity
  • 20-90% Relative Humidity @ 0~40°C (Non-Condensing)
Noise Level
  • Less than 45dB @ 1 MeterLess than 55dB @ 1 Meter
Regulations
  • EN 62040-1:2008, EN 62040-2:2006, EN 61000-4-2:2009
MAnagement
Smart RS232
  • Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
Package Content

Included

  • Please contact regional sales staff for details.